Switchgear & Ring Main Unit

Product

GZDW DC panel

Dc panel is used in large, small and medium-sized power plants and substations, providing DC power supply for high-voltage switch in normal operation and emergency state, relay protection, automatic control, accident lighting, etc. The reliability of DC panel can not be replaced by other power supply devices. It can meet the high reliability requirements of power supply in substation and power plant.

This series of DC panel is small size, high efficiency, superior technical indicators, modular design, n+1 redundancy heat backup, high reliability, the module adopts the world’s leading “resonant voltage type double circuit control resonant switching power supply technology”, “four remote”function, equipped with standard RS-485 and RS232 interface easy to connect with the automation system. And other performance is superior to the absolute advantage of traditional power and accepted by the majority of users. This product conforms to:GB/T19826-2005 “Electric power Engineering DC power equipment general technical conditions and safety requirements”; JB/T5777.4-2000 “Power System DC power equipment general technical conditions and Safety requirements’;JB/T8456-1996 “Low-voltage DC Switchgear set”;DL/T459-2000 “Power System DC Power cabinet ordering Technical Conditions”; DL/T5041-95 Technical Regulations for the Design of Communications in Thermal Power Plants.

Overview

Installation conditions

Altitude: ≤2000m;

Environment temperature: Not lower than-15℃, not higher than+40℃,

storage environment temperature is-40℃~+60℃;

Maximum relative humidity: not  exceeding 90%(Environment temperature 25℃);

The operating location is free of conductive dust, corrosive and insulating gas or vapors. When used indoors, avoid direct sunlight.

Special usage situations that do not meet the above conditions should be raised when placing an order to ensure that this product can work reliably.

Model And Meaning

KYN550 Indoor metal clad switchgear (2)

Main technical parameters

· AC input

Voltage: three-phase AC380V±20%

Frequency: 50 Hz±2%

· DC output

Voltage output: 110Vor 220V

· Stable voltage accuracy: ±0.5%

· Stable current accuracy: ±1%

· Ripple coefficient: ≤0.5%

· Parallel uneven flow rate: ±3%

· Control busbar: 5A、8A、10A、12A、15A、20A、30A、40A、50A、80A、100A.

· Closing busbar: 120A、240A、480A、720A.

· Battery capacity

Lead acid battery: 7AH、17AH、40AH、65AH、100AH、200AH、300AH、400AH、500AH、600A

H、800AH、1000AH、1500AH、2000AH、3000AH.

· Nickel separated battery: 10AH、20AH、40AH、65AH、100AH、200AH、300AH、400AH、500AH.

· Protection level: IP30

· Input power factor: ≥0.93

· Charging efficiency: ≥95%

· Maximum audibe noise(dB): ≤40

· Insulation strength: AC2500V/1min

Item Unit Parameters
Rated voltage kV 3.6、7.2、12
Rated frequency Hz 50
Rated current of circuit breaker A 630、1250
Rated current of switchgear A 630、1250
Rated dynamic stable current(4s) kA 16、20、25、31.5
Rated dynamic stable current(Peak) kA 40、50、63、80
Rated short-circuit breaking current kA 16、20、25、31.5

Rated short-circuit breaking current (Peak)

kA 40、50、63、80
Rated insulation level 1min Power frequency withstand voltage KV 24 32 42
Lightning impulse

withstand voltage

kV 40 60 75
Protection level The enclosure is IP4X, and when the doors between compartments and circuit breakers are opened, it is IP2X

Overall dimension diagram

KYN550 Indoor metal clad switchgear (3)KYN550 Indoor metal clad switchgear (1)

WhatsApp
+86 13968737027
Phone
+86 189 6895 3236
Email
jubangexport@mccb.cn