Switchgear & Ring Main Unit

Product

GT-HRM-12 Environmental protection gas insulated ring main unit

GT-HRM-12 environmental protection gas insulated ring main unit is a 12kV ring main unit standardized customized product independently developed by Jubang Group Co., Ltd. 

Overview

Description

In response to the standardization construction of national distribution network, meeting the principles of safety, reliability, robustness, universality and interchangeability, and improving the operation and maintenance reliability of ring main unit. The products are fully introduced with advanced production equipment and manufacturing technology, and the combination scheme is flexible. The unit or common box structure can be used. At the same time, the air box uses the safe and environmentally friendly mixed gas to replace SF6 as the insulating medium, which solves the problem of SF6 gas leakage and pollution, and reduces the delivery cycle.

Model And Meaning

GT-HRM-12 Environmental protection gas insulated ring main unit (1)

Features

High strength, high sealing

The core parts of the switching equipment are covered with 2.5mm thick high-quality stainless steel by laser welding, which ensures the airbox sealing reliability, high mechanical strength, good corrosion resistance, and the protection  level of the inflatable enclosure reaches IP67; The air box is equipped with explosion-proof diaphragm, which can effectively prevent the damage to people and equipment when the air pressure is too high. All conductive parts are enclosed in the air box, which not only avoids the influence of external environmental factors, but also improves the operation reliability, making it maintenance-free and conforming to the features of miniaturization.

Environmental protection and pollution-free

The insulating medium is zero-level dry air or 99.99% pure N2 in accordance with GB/T 8979-2008. The leakAge of gas will not cause any impact on the external environment, without any recycling treatment.

Perfect mechanical interlocking

With perfect five-guard mechanical interlocking function, all the interlocking functions have been configured in the internal, please operate according to the order of operation instructions, very easy to use.

Flexible and changeable extended design

Modular design, can be a variety of modules through the special busbar connector, diversified unit combination, the maximum to meet the complex and diverse distribution design scheme in China.

Visible fracture

① The earth inspection window adopts the optical imaging principle to maximize the viewing Angle inside the switch.

② The light source is set inside the air box, and the inspection window is used to make the field of vision clear.

③ The lighting source uses LED lamp design, which guarantees the design life of the lamp reliably.

Installation conditions

Altitude: ≤ 2000m;

Environment temperature :-40℃ ~+40℃ , the average temperature within 24 hours does not exceed 35℃ ;

Environment humidity: The average 24-hour relative humidity does not exceed 95%. The average monthly relative humidity does not exceed 90%;

Installation environment: the surrounding air is free from explosive and corrosive gases and fire, and the installation site is free from violent vibration impact;

Seismic capacity :8 degrees, ground horizontal acceleration ≤ 0.4g, ground vertical acceleration ≤ 0.2g.

Note: If the operating environment exceeds the above range, please contact our company.

Technial Parameters

Item Unit Circuit breaker Load switch
Rated voltage kV 12 12
Rated current A 630 630
Rated frequency Hz 50 50
Rated

insulation level

1 min Power frequency withstand voltage (Phase-to-phase and Phase-to-ground) kV 42 42
1 min Power frequency withstand voltage (Isolating fracture) kV 48 48
Power frequency withstand voltage (Control and auxiliary circuits) kV 2 2
Lightning shock withstand voltage

(Phase-to-phase and Phase-to-ground)

kV 75 75
Lightning shock withstand voltage (Isolating fracture) kV 85 85
Rated short-circuit breaking current kA 20 20
Rated short-circuit closing current kA 50 50
Rated short-time withstand current kA 20 20
Rated short circuit duration s 4 4
Rated peak withstand current kA 50 50
Take-over current/ Transfer current A
Rated operation sequence

0-0.3s-CO-180s-CO

 
Rated inflation pressure (gauge pressure at 20℃ ) MPa 0.02  
Annual gas leakAge rate ≤ 0.01%  
Mechanical life Times 10000 10000
Main circuit resistance μΩ ≤ 180 ≤ 180

Overall dimension diagram

GT-HRM-12 Environmental protection gas insulated ring main unit (2)
Unit A(mm)
Unit 1 420
Unit 2 840
Unit 3 1260
WhatsApp
+86 13968737027
Phone
+86 189 6895 3236
Email
jubangexport@mccb.cn