Power Transformer

Product

SZ11 Series 35KV Oil immersed Power Transformer

SZ11 Series 35KV oil-immersed transformers are essential power transmission and distribution equipment in medium-voltage power systems, playing a critical role in voltage conversion and power distribution. Their core function is to step down high-voltage electricity (typically from 35KV or higher transmission networks) to the 6-10KV medium-voltage level for safe delivery to industrial plants, commercial complexes, and residential communities, or to step up low-voltage power generated by small-scale power sources (such as industrial self-provided generators) to 6-10KV for grid connection. This voltage regulation process ensures efficient, stable, and safe power supply to end-users while minimizing energy loss during transmission.

Overview

Model And Meaning

Product model

Loss level

Special purpose or special structure

Rated capacity kV.A

System nominal voltage kV

Special usage environment

Energy efficiency level

D-Single-phase

S-Three-phase

F-Air cooling

Z-On load voltage regulation
11

13

14

20

22
M-Fully sealed
M.RL-Fully sealed
three-dimensional coil iron core
    GY-Plateau

TA-Tropic

TH-Humid tropical zone
NX3

NX2

NX1

Features

The three-phase oil immersed distribution transformer produced by our company adopts a new insulation structure on the body, which improves the ability to withstand short circuits; The iron core is made of high-quality cold-rolled silicon steel sheets; The high-voltage winding is made of high-quality oxygen free copper wire and adopts a multi-layer cylindrical structure; All fasteners are treated with special anti-corrosion measures. Adopting a corrugated oil tank and a fully sealed structure.The product has the characteristics of high efficiency and low loss, which can save a lot of electricity consumption and operating costs. It has significant social benefits and is a high-tech product promoted by the country.

Reliable structure

Our company has made many improvements based on traditional structure and mature technology, such as adopting:

① Spiral coils with longitudinal oil ducts provide better internal heat dissipation;

② Improved the effective support of the coil end face, resulting in stronger resistance to short circuit currents;

③ We have adopted new lifting structures and body positioning structures to ensure greater reliability during long-distance transportation and operation;

④ We also have many unique and reliable structures to serve you;

⑤ Choosing transformers with higher performance levels will have a higher level of technical content.

⑥ The oil tank adopts a fully sealed structure, which isolates the transformer from the atmosphere, prevents and slows down oil degradation and insulation moisture, enhances operational reliability, and eliminates maintenance during normal operation.

High quality materials

All raw materials have undergone quality inspection, and all raw material manufacturers have undergone strict review in accordance with the national standard ISO9000.

① Select oxygen free copper wire with lower resistivity and undergo a series of additional surface treatments to make it smoother, without burrs or sharp corners, resulting in lower load loss and more reliable electrical performance of the transformer.

② Select high-quality silicon steel sheets, and with the improvement of performance level, use silicon steel sheets with lower unit loss to reduce no-load loss of transformers.

③ Using high-quality laminated wood insulation components, it will never crack and will not move even under the action of short-circuit current.

④ Selecting transformer oil that has undergone deep filtration has lower levels of water, gas, and impurities, making transformer operation more reliable

⑤ Select high-quality rubber sealing materials to effectively prevent aging and prevent leakage.

Normal usage conditions

Altitude: Not exceeding 1000m;

Environmental temperature: Maximum temperature+40 ℃; The average temperature of the hottest month is+30 ℃; Maximum annual average temperature+20 ℃; The minimum outdoor temperature is -25 ℃. The waveform of the power supply voltage is approximately a sine waveFor three-phase transformers, the three-phase power supply voltage should be roughly symmetrical

Installation environment: No obvious pollution in the installation environment; Ground acceleration caused by earthquake ag: Horizontal direction below 3m/s², vertical direction below 1.5m/s²

Special usage conditions

Any special usage conditions that need to meet the normal usage conditions of the transformer should be explained during the inquiry and ordering process.

Technial Parameters

Rated

capacity

kV.A

Voltage combination kV Connection

group

Loss kW No-load

current

%

Short-

circuit

impedance

%

Weight kg Overall dimensions

(mm)

L×W×H

Gauge

Vertical/

Horizontal

High

voltage

High

voltage tap

range %

Low

voltage

No-

load

Load Body

weight

Oil

weight

Total

weight

800 35 ±3×2.5 6.3

10.5
Yd11 1.25 9.88 0.9 6.5 1735 995 3625 2790×1220×2130 820/820
1000 1.50 12.16 0.9 2015 1105 4055 2830×1240×2150
1250 1.77 14.63 0.81 2190 1155 4580 2870×1310×2210
1600 2.16 17.48 0.77 2535 1295 5245 2875×1310×2380
2000 2.30 19.20 0.50 2855 1345 5935 2980×2880×2380 1070/1070
2500 2.72 20.60 0.50 3815 1575 6745 3060×2190×2490
3150 35~

38.5

3.23 24.70 0.50 7.0 4235 1860 8780 3180×2240×2510
4000 3.87 29.10 0.50 5230 2260 9820 3270×2410×2600
5000 4.64 34.20 0.50 6195 2545 11510 3490×2480×2840
6300 5.63 36.70 0.50 8.0 8315 3095 14805 3710×2600×3005 1475/1475
8000 6.3

6.6
10.5

11
YNd11 7.87 40.60 0.40 9870 3480 16590 3850×2680×3230
10000 9.28 48.00 0.40 11025 4160 19930 3960×2750×3310
12500 10.0 56.80 0.35 14270 5265 24295 4035×2980×3530
16000 13.1 70.30 0.35 17780 6280 28720 4140×3200×3660
20000 15.5 82.70 0.30 20205 7415 37380 4070×3580×4170
25000 18.3 97.8 0.30 10.0 24950 9030 43425 4710×4120×4310 2040/2040
31500 21.8 116.00 0.30 29820 11025 51555 5360×4570×4450

Note: ① For transformers with low voltage of 10.5kV, products with connection group number Dyn11 can be provided.

② The maximum current tap is -7.5% at the tap position.