The RM AirSeT Environmental protection gas insulated ring main unit is fully insulated and sealed according to GB and IEC standards, and does not require replenishment during the product life cycle.
Suitable for harsh environments.
Compact design, 3-position load switch: closing opening isolation earthing, multiple solutions to meet more stringent requirements.
| NO | product name | Model | Qty | ||
| 1 | indicator light | 220 | |||
| mutifuctional meter | RI194E-9S4 96*96 92*92 | 2 | |||
| 2 | CT | BH0.66 40I 400/5 0.5 class | 3 | ||
| CT | BH0.66 40I 600/5 0.5 class | 6 | |||
| fuse base | NT00 | 68 | |||
| 3 | disconnector | HD13BX-630/31 | 2 | ||
| 4 | disconnector | HD13BX-630/31 | 2 | ||
| 5 | disconnector | HD13BX-630/31 | 2 | ||
| 6 | disconnector | HD13BX-1000/31 | 1 | ||
| 7 | disconnector | HD13BX-1000/31 | 1 | ||
| 8 | disconnector | HD13BX-200/31 | 4 | ||
| 9 | disconnector | HD13BX-400/31 | 2 | ||
| 10 | disconnector | HD13BX-400/31 | 2 | ||
| 11 | disconnector | HD13BX-400/31 | 1 | ||
| 12 | disconnector | HD13BX-400/31 | 1 | ||
| 13 | disconnector | HD13BX-200/31 | 1 | ||
| 14 | disconnector | HD13BX-400/31 | 2 | ||
| 15 | disconnector | HD13BX-400/31 | 2 | ||
| 16 | CT | BH0.66 30I 250/5 0.5 class | 15 | ||
| CT | BH0.66 30I 400/5 0.5 class | 21 | |||
| CT | BH0.66 40I 600/5 0.5 class | 12 | |||
| CT | BH0.66 50I 750/5 0.5 class | 6 | |||
| CT | BH0.66 40I 400/5 0.5 class | 6 | |||
| 17 | temp controller | 1 | |||
| mutifuctional meter | RI194E-9S4 96*96 92*92 | 4 | |||
| SPD | NXU-II G 40KA/440 4P | 4 | |||
| fuse | NT00 32A | 96 | |||
| fuse base | NT00 | 12 | |||
| 18 | contatctor | CJ19-95 | 10 | ||
| 19 | contatctor | CJ19-63 | 10 | ||
| 20 | contatctor | CJ19-63 | 10 | ||
| 21 | mutifuctional meter | RI194E-9S4 96*96 92*92 | 18 | ||
| 22 | contatctor | CJ19-95 | 10 | ||
| 23 | contatctor | CJ19-63 | 10 | ||
| 24 | thermal relay | JR36-63 120A | 20 | ||
| temp controller | 8 | ||||
| 25 | thermal relay | JR36-63 45A | 60 | ||
| 26 | MCB | NXB-125 3P D100 | 20 | ||
| SPD | NXU-II G 40KA/440 4P | 16 | |||
| 27 | temp controller | 15 | |||
| 28 | MCB | NXB-63 3P D63 | 60 | ||
| 29 | contatctor | CJ19-43 | 30 | ||
| 30 | MCB | NXB-63 3P D40 | 60 | ||
| 31 | MCB | NXB-63 3P D40 | 51 | ||
| SPD | NXU-II G 40KA/440 4P | 3 | |||
| 32 | thermal relay | JR36-63 63A | 60 | ||
| 33 | contatctor | CJ19-43 | 21 | ||
| fuse handle | 2 | ||||
| 34 | contatctor | CJ19-43 | 30 | ||
| 35 | contatctor | CJ19-43 | 30 | ||
| 36 | thermal relay | JR36-63 45A | 51 | ||
| 37 | contatctor | CJ19-63 | 10 | ||
| 38 | contatctor | CJ19-63 | 10 | ||
| 39 | contatctor | CJ19-63 | 10 | ||
| 40 | earthing busbar | / | 23 | ||
| zero busbar | / | 23 | |||
| vertical busbar | / | 69 | |||
| 41 | disconnector accessory |
||||
| 42 | srews | ||||
| 43 | srews | ||||
| 44 | insulator | 48 | |||
| 45 | busbar truck | 12 | |||
| 46 | 325KVAR primary connnection wire | 3 set | |||
| 47 | 200KVAR primary connnection wire | 7 set | |||
| 48 | 350KVAR primary connnection wire | 2 set | |||
| 49 | 300KVAR primary connnection wire | 3 set | |||
| 50 | 125KVAR primary connnection wire | 5 set | |||
| 51 | 225KVAR primary connnection wire | 3 set | |||
| 52 | hand wrench | 16 | |||
| hand screwdriver | 24 | ||||
| cutting disk | 124 | ||||
| fuse base | 12 | ||||
| 53 | busbar truck | 12 | |||
| 54 | capacitor controller | 12 | |||
| 55 | capacitor controller | 12 | |||
| 56 | 125mm angle grinder | 1 | |||
| electrical screwdriver | 1 | ||||
| electrical wrench | 1 | ||||
| 57 | 150mm angle grinder | 1 | |||
| electrical screwdriver | 1 | ||||
| electrical wrench | 1 | ||||
| 58 | blank nameplate | 24 | |||
| keys | 50 | ||||
Robust design
The structure of insulated metal enclosed switchgear reduces the
difficulty of maintenance operations.
With an undisputed leading position in the field of medium voltage
secondary switchgear, the company has conducted a comprehensive
experience feedback evaluation to improve quality and provide
outstanding benefits:
• 30 years of research and development experience
• No need to refill the gas
• Long mechanical life
• New operating mechanism
• Composite materials require no lubrication and are already used
extensively in the aviation and automotive industries
Totipotent architecture
The RM AirSeT Environmental protection gas insulated ring main unit
(GIS) mainly used for medium voltage secondary distribution.
Can achieve 1-6 function common box, usually used in ring network or
radiation distribution network connection, isolation or earthing.
Thanks to the new vacuum circuit breaker, RM AirSeT enables new
applications such as closed-loop power distribution solutions:
• Automatic transfer switch(ATS)
• Closed-loop distribution network
• Automatic reclosing
Based on the successful concept of “free combination” launched by the
company on the RM6 series a few years ago, RM AirSeT provides a more
flexible combination solution:
• Easy to expand: The switchgear can be freely combined
• Up to 6 functions can be achieved in a shared box
• Modular design
Digitization
RM AirSeT has all the functions required for a smart grid Plug and
play: can be upgraded electrically on-site.
Optimized asset management: based on environmental monitoring sensor
technology (temperature, humidity, flood, intrusion…)
Openness: compatible with both company and other brand DTU
Progressiveness: provide highly integrated intelligent ring network
cabinet, including many functions such as distributed DTU Easergy
T300
Installation conditions
Environmental temperature: Lower or equal to 40 ℃ ; Above or equal to
-25 ℃ (For low-temperature use, please consult the manufacturer)
Altitude: ≤ 1000m (above 1000m, please consult the manufacturer).
Humidity: Less than or equal to 95% (24 hours); Less than or equal to
90% (1 month)
Main technical parameters
| RM AirSet–Customization | RM AirSet | ||||
| Plug and play | Easy component replacement before/after installation |
Yes | |||
| The operational continuity level defined in GB/T 3906 |
|||||
| Other high-voltage compartments or functional units remain energized |
LSC 1: Low running continuity | LSC | LSC 2 | ||
| LSC 2: Higher operational continuity | ● | ||||
| Partition between compartments | PI: Low safety: Insulation partition | PI | PM | ||
| PM: Higher safety: Metal earthing | ● | ||||
| Insulation and disconnection | |||||
| Switching technology | Parallel vacuum interruption technology (SVI) TM or vacuum circuit breaker |
||||
| Working principle | 3-station load switch | ||||
| Extended durability level Comply with GB/T 1984 and GB/T 1985 definitions for circuit breakers and isolating switches |
Yes | ||||
| Breaking medium | Vacuum arc extinguishing chamber | ||||
| Insulation medium | Dry air (1) | ||||
| Relative inflation pressure | 20℃,12kV | MPa | 0.04 | ||
| Insulation level – withstand voltage |
|||||
| Rated voltage | Ur | kV | 12 | ||
| Rated frequency (F) | fr | Hz | 50 | ||
| Rated power frequency withstand voltage | Ud | Interphase& opposite | kV(1min RMS) | 42 | |
| Fracture | 48 | ||||
| Rated lightning impulse withstand voltage | Up | Interphase& opposite | kV(1.2μs) | 75 | |
| Fracture | 85 | ||||
| Current | |||||
| Rated current – busbar | Ir | Meets 1.1Ir 630A | 630A | ||
| Short-time withstand current | Ik | kA | 20 | ||
| Duration | tk/tke | s | 4s/3s | ||
| Rated peak withstand current | Ip | kA | 50 | ||
| Enclosure protection level | |||||
| Enclosure Comply with GB/T 4208 standard |
Air box | IP67 | |||
| Cable room | IP4X | ||||
| Institutional Room | IP4X | ||||
| Internal pressure interval | IP4X | ||||
| Internal Comply with GB/T 4208 standard | Septum | IP2X | |||
| Mechanical impact protection level |
|||||
| IK code | Comply with GB/T 20138 | IK07 | |||
| Internal arc fault tolerance | |||||
| Basis | Unclassified | ||||
| A FL | Front and side | kA | 20 | ||
| Grade A | A FLR | Front side and rear | kA | 20 | |
| Duration | s | 1s | |||
| Recycling precautions | |||||
| Non-recyclable components: maximum volume/weight ratio (solid insulation, spray materials,…) |
< 1%/ < 5% | ||||
| Other materials (steel, stainless steel, copper, aluminum, recyclable compliant materials…) |
100% recyclable | ||||
| Specific processing procedures for gas operation/recover |
No harmful gases (air only) | ||||
| No SF6 technology | Gas insulated switchgear: The enclosure definition complies with GB/T 3906 standard |
Yes – Sealing pressure system GIS | |||
| Service life | Year | 40(2) | |||
Note: ① Pure air from the factory (dry, filtered, pressurized) does
not require further air replenishment
② Under normal usage conditions specified in GB/T11022
RM AirSet consists of the following components:
1. A stainless steel gas box filled with pressurized, filtered, and
dried air, sealed for life, with a busbar and all live switching
components inside, such as load switches, earthing switches, fuse
assemblies, or circuit breakers
2. One to six cable bays, connected to the power grid or load
(usually transformers)
3. User interface with single line diagram, operating mechanism, and
low-voltage components
4. Manual or electric operating mechanism room
5. With visible earthing
Selection of functional units
| Name | C | F | V | V | D | PT |
| Function | Grid connection | Transformer protection | Power grid or transformer protection | Grid connection | Auxiliary power
supply& measurement |
|
| Main device | 3-station load switch | Load switch fuse
combination electrical appliances |
Vacuum circuit breaker | Lifting cabinet | Voltage transformer cabinet | |
| Primary
diagram |
|
|
|
|
|
|
| Isolation | Isolation strip SVI ™ Load switch | With SVI ™ Load switch fuse
combination |
3-station isolation switch | Lifting cabinet | 3-station isolation switch | |
| Earthing | Cable earthing switch | Cable earthing switch | Cable earthing switch with circuit breaker | Cable earthing switch | Cable earthing switch | |
| Abbreviation/ Remarks | Load switch(LBS) | Combination electrical appliances | Upper isolation circuit breaker | Lower isolation circuit breaker | (Earthing switch optional) | (PT420 or PT600) |
| Symbol |
|
|
|
|
|
|
Restrictions on free combination
① For special customization, please consult the manufacturer.
② PT (Voltage transformer cabinet) and M (metering cabinet) are
independent: PT cabinet and M cabinet are specific functional units.
Can only be modular and cannot be containerized. Can only be
connected through scalable RM AirSeT (PT).